Reliable CDCP Dumps Sheet | CDCP Relevant Questions
CDCP certification exam opens the doors for starting a bright career. After passing the Certified Data Centre Professional (CDCP) CDCP test you will easily apply for well-paid jobs in top companies all over the world. CDCP exam offers multiple advantages including, high salaries, promotions, enhancing resumes, and skills improvement. Once you pass the CDCP Exam, you can avail all these benefits. If you want to pass the EXIN CDCP certification exam, you must find the best resource to prepare for the CDCP test.
You will feel convenient if you buy our product not only because our CDCP exam prep is of high pass rate but also our service is also perfect. What’s more, our update can provide the latest and most useful CDCP exam guide to you, in order to help you learn more and master more. We provide great customer service before and after the sale and different versions for you to choose, you can download our free demo to check the quality of our CDCP Guide Torrent. You will never be disappointed.
>> Reliable CDCP Dumps Sheet <<
CDCP Relevant Questions - CDCP Trusted Exam Resource
We don't just want to make profitable deals, but also to help our users pass the exams with the least amount of time to get CDCP certificate. Choosing our CDCP exam practice, you only need to spend 20-30 hours to prepare for the exam. Maybe you will ask whether such a short time can finish all the content, we want to tell you that you can rest assured ,because our CDCP Learning Materials are closely related to the exam outline and the questions of our CDCP guide questions are related to the latest and basic knowledge. You will pass the CDCP exam only with our CDCP exam questions.
EXIN CDCP Exam Syllabus Topics:
Topic
Details
Topic 1
Topic 2
Topic 3
Topic 4
Topic 5
Topic 6
Topic 7
Topic 8
Topic 9
Topic 10
Topic 11
EXIN Certified Data Centre Professional (CDCP) Sample Questions (Q55-Q60):
NEW QUESTION # 55
What should be considered when implementing hot- or cold-aisle containment in an existing computer room?
Answer: B
Explanation:
Hot- or cold-aisle containment is a strategy to improve the cooling efficiency and reduce the energy consumption of data centers by isolating the hot exhaust air from the cold supply air. However, implementing this strategy in an existing computer room may create potential issues with the existing fire suppression system (s), such as:
*The containment barriers may interfere with the distribution and activation of the fire suppression agents, such as water, gas, or aerosol, and reduce their effectiveness in extinguishing a fire.
*The containment barriers may create pockets of high temperature and pressure that could damage the equipment or the containment structure itself in the event of a fire.
*The containment barriers may obstruct the access and visibility of the fire detection and alarm devices, such as smoke detectors, heat sensors, or manual call points, and delay the response time of the fire suppression system(s).
*The containment barriers may violate the local fire codes and regulations that specify the minimum clearance and ventilation requirements for the data center.
Therefore, when implementing hot- or cold-aisle containment in an existing computer room, it is important to consider the impact on the existing fire suppression system(s) and take appropriate measures to ensure the safety and compliance of the data center, such as:
*Consulting with the fire authorities and the fire suppression system vendor to assess the compatibility and suitability of the containment solution with the existing fire suppression system(s).
*Modifying or upgrading the existing fire suppression system(s) to accommodate the containment solution, such as relocating or adding fire suppression devices, adjusting the discharge rate and pressure, or installing a secondary fire suppression system within the contained area.
*Installing fire-rated containment barriers that can withstand high temperatures and resist the spread of fire and smoke, and that have self-closing or automatic release mechanisms in case of a fire.
*Installing fire detection and alarm devices within the contained area and ensuring their proper integration and communication with the existing fire suppression system(s).
*Conducting regular testing and maintenance of the fire suppression system(s) and the containment solution to ensure their functionality and reliability.
References: EPI Data Centre Framework, Module 4: Fire Protection, page 10-11. EPI Data Centre Professional (CDCP) Reference Materials, page 66-67. 1, 2, 3.
NEW QUESTION # 56
The temperature and humidity values indicated on the display of the Computer room air conditioner unit are the values measured at which point?
Answer: D
Explanation:
According to the IBM document on temperature and humidity design criteria1, the temperature and humidity values indicated on the display of the computer room air conditioner unit are the values measured at the intake of the air conditioner. This is because the intake is where the air conditioner draws the air from the computer room and cools and dehumidifies it before sending it back to the computer room. The display shows the current conditions of the computer room air, which are used to adjust the cooling and dehumidifying operations of the air conditioner. The values measured at the exhaust (outlet) of the air conditioner are not displayed, as they are not relevant for the computer room environment. The values measured at the front of the rack of the aisle the air conditioner is situated are also not displayed, as they may vary depending on the distance and location of the rack. The average value between the intake and exhaust (outlet) of the air conditioner is not displayed, as it does not reflect the actual conditions of the computer room air or the air conditioner performance.
References: 1: Temperature and humidity design criteria - IBM
NEW QUESTION # 57
What is a requirement of an FM200 (HFC-227) installation?
Answer: A
Explanation:
FM200 (HFC-227) is a clean agent fire suppression system that uses a high-pressure gas to extinguish fires by reducing the oxygen concentration and absorbing the heat. FM200 is stored in cylinders at pressures of up to
42 bar (600 psi) and is released through nozzles into the protected area. Because of the high pressure, the nozzles must be mounted with two brackets to prevent them from moving or breaking during discharge. The brackets must be securely attached to the ceiling or wall and aligned with the nozzle outlet. The nozzle outlet must also be free of any obstructions that could affect the discharge pattern or distribution.
References:
*EPI Data Centre Professional (CDCP®) Preparation Guide, page 32
*FSL-227 Technical Manual, page 10
*Firetrace ILP Manual, page 21
NEW QUESTION # 58
What is a requirement for both CCTV cameras and recording equipment?
Answer: C
Explanation:
A UPS (Uninterruptible Power Supply) is a device that provides backup power to electrical equipment in case of a power outage or fluctuation. A UPS is essential for both CCTV cameras and recording equipment, as it ensures that the surveillance system can continue to operate and record without interruption or data loss. A UPS can also protect the CCTV cameras and recording equipment from damage caused by power surges or spikes. Connecting both CCTV cameras and recording equipment to a UPS is a requirement for data centres, as it enhances the security and reliability of the surveillance system.
References: Technical Specification - GeM, [What is a UPS? | Uninterruptible Power Supply | APC by Schneider Electric], [Why You Need a UPS for Your CCTV System - CCTV Camera World].
NEW QUESTION # 59
Which design consideration should be implemented with an Inergen-based fire suppression system?
Answer: D
Explanation:
A design consideration that should be implemented with an Inergen-based fire suppression system is to install pressure relief valves in the room that needs protection. Inergen is a clean agent fire suppression system that uses a mixture of inert gases (nitrogen, argon, and carbon dioxide) to displace the oxygen in the room and extinguish the fire. However, when Inergen is released into the room, it creates a sudden increase in pressure, which can damage the walls, doors, windows, and ceilings of the room. To prevent this, pressure relief valves are required to vent the excess pressure to the outside and maintain a safe pressure level inside the room.
Pressure relief valves should be designed and installed in accordance with the relevant standards and codes, such as NFPA 2001 and ISO 14520.
References:
1: CDCP Preparation Guide, page 24, section 2.4.3 2: Data Center Fire Suppression Systems Bring Unexpected Risk3, page 1, section 1 4: Inergen from Fire Eater - CSC Datacenter5, page 1, section 1 6:
Inergen Fire Suppression System7, page 1, section 1
NEW QUESTION # 60
......
As you know, when choosing a learning product, what we should value most is its content. The content of CDCP study materials is absolutely rich. Our company collected a lot of information, and then our team of experts really spent a lot of energy to analyze and sort out this information. If you buy our CDCP Exam Questions, then you will find that the information compiled is all about the keypoints and the latest. And we always keep on updating our CDCP training quiz.
CDCP Relevant Questions: https://www.actual4dump.com/EXIN/CDCP-actualtests-dumps.html
Exceptional tutoring services for academic success. Personalized instruction. Highly qualified tutors. Flexible scheduling. Achieve your goals with us!
Boost your academic performance with our exceptional tutoring services. Personalized instruction, qualified tutors, flexible scheduling—your path to success starts here!
© 2024 Eagle Star Tutoring Center